FPC-82243-CON Panel IP56 with Inner Door Single Or Three Phase DOL 0.1-16amp HydroSTART – Matelec – Stormwater or Sewage FPC-82143-CON FPC-82141-CON For Conductivity Probes
$2,040.00 – $3,340.00
FPC-82243-CON Dual three phase pumps 0.1 – 16a panel w/- inner door IP56 powder coated enclosure
FPC-82243-CON-SS Dual three phase pumps 0.1 – 16a panel w/- inner door IP56 316 stainless steel enclosure
FPC-82143-CON Single three phase pump 0.1 – 16a panel w/- inner door IP56 powder coated enclosure
FPC-82141-CON Single single phase pump 0.1 – 16a panel w/- inner door IP56 powder coated enclosure
FPC-82241-CON Dual single phase pump 0.1 – 16a panel w/- inner door IP56 powder coated enclosure
Power : Three Phase 400/3/50 Single Phase 230/1/50
Enclosure size:
Powdered coated steel: 400 x 300 x 150+
Stainless steel enclosure 500 x 400 x 150+ check at time of ordering
Supplied with touch pad and mains isolator on powder coated inner door
- Description
- Additional information
- Downloads
Description
Australia’s HydroSTART controller brings the features of the standard single and dual pump controllers.
Redesigned capacitive touch keypad and control module with pump current sensing, providing with range electronic overload
Australian Made – all electronic PCBs are being manufactured in Australia including the control touchpads
Pump level status showing on touchpad – indicator lights for each level input is standard
Functions:
Level control mode – Level empty or filling operation controlled by conductivity probes
Duty sharing and alternation – Duty pump alternates on pump start and after 30 minutes of continuous running in alternation
mode, or 6 hours of accumulated running in recirculation mode
Staggered pump start – Prevents excessive current draw and reduces water surge
Manual pump control – Manual pump mode with optional 5 minute timeout to revert to auto mode
System enable input – Enables and disables the system in auto mode
Static duty mode – No duty alternation, for applications using smaller duty pump that always starts first
Smart chirp mode alarms – Audible alarm automatically silences after 5 minutes if not muted, then chirps every 5 minutes
Fault Protection:
High level alarm – Alarms after 15 minute delay with auto reset in stormwater mode, or after 1 minute with manual reset only in
sewage mode
Low level protection – Alarms and shuts down pumps on low level, manual reset only
Low pressure protection – Alarms and shuts down pumps if low pressure input is closed for 60 seconds
Pump anti-seize protection – Runs pumps periodically during low use to prevent seizing
Pump current sensing – Provides adjustable pump overload
Additional information
| Weight | N/A |
|---|---|
| Dimensions | N/A |
| Size | FPC-82141-CON used with conductivity probes, FPC-82143-CON used with conductivity probes, FPC-82241-CON used with conductivity probes, FPC-82243-CON used with conductivity probes, FPC-82243-CON-SS used with conductivity probes |