FPC-70000 Range
FPC-70011 Single Phase & FPC-70013 Three Phase Jockey/Jacking Pump Controller is designed to provide control and status indication for a jockey/jacking pump, compliant with the current Australian Standards (AS 2941-2013: Section 5).
Housed in a red powder coated metal enclosure, the controller features pump overload protection, a digital input for automatic pump control and an LCD screen/keypad interface with pump status indication, logged data and auto/off/manual control.
Enclosure:
IP54 rated, powder coated mild steel enclosure with removable gland plate
Protection:
Mains power isolator switch (pad-lockable in on position)
Circuit breaker protected low voltage control and input circuitry
Contactor and thermal overload protection of pump
Din rail mounted terminal connections
Control & interface:
HMI with backlit LCD screen and keypad:
System and pump status overview screen
Auto, off/reset and manual control buttons
Logged data for start and fault counters, pump run hours
Jacking pump controller PCB control module
Config button for adjusting settings, resetting logged data
Inputs:
Single phase (230Vac) or three phase (400Vac) power supply
Digital 12Vdc input for pressure switch/pump start signal
Outputs:
Pump supply output
BMS volt free output for pump fault
Function Features:
Provides status indication and control for a jockey/jacking pump, compliant with the current Australian Standards
Automatic control via digital input
Momentary manual pump run while manual button is held down, before returning to auto
Momentary pump off while off/reset button is held down, before returning to auto
Optional pump run timer keeps pump running for adjustable period of time after the pump start input opens
Fault Protection:
Pump overload protection shuts down pump on overload

Jockey/Jacking Pump Range

CodePhase / VoltageOverload Rating OptionsEnclosure Size
FPC-700111 Phase / 230Vac-AA to -E300x300x150mm
FPC-700133 Phase / 400Vac-AA to -E300x300x150mm

Overload Rating Guide

Code SuffixAmp Rating
-AA1.6 – 2.5 Amp
-A2.5 – 4 Amp
-B4 – 6 Amp
-BB5.5 – 8 Amp
-C7 – 10 Amp
-D9 – 13 Amp
-E12 – 18 Amp

Additional overload ratings available on request

Additional information

WeightN/A
DimensionsN/A
Size

FPC-70011-A Fire Pump Controllers – Jockey – Jacking Pump, FPC-70011-C Fire Pump Controllers – Jockey – Jacking Pump, FPC-70011-E Fire Pump Controllers – Jockey – Jacking Pump, FPC-70013-A Fire Pump Controllers – Jockey – Jacking Pump, FPC-70013-C Fire Pump Controllers – Jockey – Jacking Pump, FPC-70013-E Fire Pump Controllers – Jockey – Jacking Pump