FPC-82243 Dual Pump Panel IP56 with Inner Door 415/3/50 DOL 0.1-16amp HydroSTART Two (2) Pump Controller – Matelec – Stormwater or Sewage Options FPC-82243-E , FPC-82243-SS , FLC-82243-E-SS
$1,480.00 – $2,890.00
FPC-82243 Dual pumps 0.1 – 16 amps panel w/- inner door IP56 Powder coated steel enclosure
FPC-82243-E Dual pumps 12 – 18 amps panel w/- inner door IP56 Powder coated steel enclosure
FPC-82243-SS Dual pumps 0.1 – 16 amps panel w/- inner door IP56 316 stainless steel enclosure
FPC-82243-E-SS Dual pumps 12 – 18 amps panel w/- inner door IP56 316 stainless steel enclosure
Power : Three Phase 400/3/50
Enclosure size:
Powdered coated steel: 400 x 300 x 150+
Stainless steel enclosure 500 x 400 x 150+ check at time of ordering
Supplied with touch pad and mains isolator on powder coated inner door
- Description
- Additional information
- Downloads
Description
Australia’s HydroSTART controller brings the features of the standard single and dual pump controllers.
Redesigned capacitive touch keypad and control module with pump current sensing, providing with range electronic overload
Australian Made – all electronic PCBs are being manufactured in Australia including the control touchpads
Pump level status showing on touchpad – indicator lights for each level input is standard
FUNCTIONS:
Level control mode – Level empty operation controlled by up to 5 float switches: Low level, duty stop, duty start, standby start and
high level
Duty sharing and alternation – Duty pump alternates on pump start and after 30 minutes of continuous running in alternation
mode, or 6 hours of accumulated running in recirculation mode
Staggered pump start – Prevents excessive current draw and reduces water surge
Manual pump control – Manual pump mode with optional 5 minute timeout to revert to auto mode
System enable input – Enables and disables the system in auto mode
Static duty mode – No duty alternation, for applications using smaller duty pump that always starts first
Smart chirp mode alarms – Audible alarm automatically silences after 5 minutes if not muted, then chirps every 5 minutes
FAULT PROTECTION:
High level alarm – Alarms after 15 minute delay with auto reset in stormwater mode, or after 1 minute with manual reset only in
sewage mode
Low level protection – Alarms and shuts down pumps on low level, manual reset only
Low pressure protection – Alarms and shuts down pumps if low pressure input is closed for 60 seconds
Prime loss protection – Alarms and shuts down running pumps if there is no flow for 30 seconds
Pump anti-seize protection – Runs pumps periodically during low use to prevent seizing
Pump current sensing – Provides adjustable pump overload
Additional information
| Weight | N/A |
|---|---|
| Dimensions | N/A |
| Size | FPC-82243 Hydrostart Dual pumps 400/3/50 0.1-16A O/L powder coated steel enclosure, FPC-82243-E Hydrostart Dual pumps 400/3/50 12-18A O/L powder coated steel enclosure, FPC-82243-E Three Phase HydroSTART 2 Pump Controller, FPC-82243-E-SS Hydrostart Dual pumps 400/3/50 12-18A O/L 316 stainless steel enclosure, FPC-82243-HR Three Phase HydroSTART 2 Pump Controller, FPC-82243-LR Three Phase HydroSTART 2 Pump Controller, FPC-82243-SS Hydrostart Dual pumps 400/3/50 0.1-16A O/L 316 stainless steel enclosure |